Keentune
Adaptive skill practice — find your level, get sharper.

EPA 608 practice test

Not the EPA — not a government website
Keentune is a private study app, not affiliated with, endorsed by, or acting for the Environmental Protection Agency, any EPA-approved certifying organization, or any government agency. It cannot certify you or give the Section 608 exam; for that, use an EPA-approved certifying organization.
The EPA Section 608 technician certification — adaptive practice for the Core exam and the Type I/II/III service material.
Start a free EPA 608 practice set
No signup · first signal after 5 answers · your score at session end
When’s your EPA 608?
You’ll get a countdown and a daily pace — a study signal, never a pass guarantee.
Or pick the exact date
EPA Section 608 certification is federally required for any technician who services or disposes of equipment containing regulated refrigerants — the ozone-depleting CFCs and HCFCs and their non-exempt substitutes, such as HFCs. The exam has four parts — a Core section everyone takes (ozone depletion, the Clean Air Act rules, refrigerant families, the three Rs, safety) plus Type I (small appliances), Type II (high-pressure systems), and Type III (low-pressure chillers); passing Core and all three types earns Universal certification.
Keentune drills both halves with questions that meet you at your level and get harder as you improve: the regulations everyone must know, and the service practices — recovery levels, evacuation targets, leak testing — that the Type sections test. Every answer comes with an explanation that names the classic mix-up, built from the public EPA regulations (40 CFR Part 82, and the AIM Act rules in 40 CFR Part 84 that now cover HFC leak repair and reclaim). It is written from the current regulations, not from any certifying organization’s question bank, so it is not keyed to a particular edition of anyone’s exam.
Your first scored practice exam is free · unlimited with Pro
See everything in Keentune Pro →

What’s on the EPA 608 exam

Sections
4 — Core + Type I, II, III
Questions
25 per section (100 total)
Passing score
70% per section — 18 of 25
Scoring
Each section scored independently
Universal
Core + all three types
Expires
No — no renewal required (as of 2026)
Exam edition
Varies by certifying org — ESCO added a 2026 bank (see FAQ)
Core
25 Q
Everyone takes it: ozone depletion and the Clean Air Act, refrigerant families, global-warming potential and safety classes (A1, A2L, A3), the three Rs, the venting prohibition (which also covers non-exempt substitutes such as HFCs), sales restriction, and cylinder safety.
Type I — small appliances
25 Q
Servicing small, factory-sealed appliances (five pounds of refrigerant or less) — recovery equipment, required recovery levels (90%/80%/4 inHg), and system-dependent vs self-contained recovery.
Type II — high-pressure
25 Q
High- and very-high-pressure systems — required recovery vacuums, leak inspection, leak-repair rules (two regimes as of 2026: one for ozone-depleting refrigerants, one for HFC systems under the AIM Act), and refrigerant-specific rules.
Type III — low-pressure
25 Q
Low-pressure chillers — deep-vacuum recovery to 25 mm Hg absolute, pressurization limits for leak detection, and low-pressure hazards.
Format and passing marks from 40 CFR Part 82 Subpart F, Appendix D (unchanged since 2016) and epa.gov; exam editions from ESCO Institute’s public Section 608 page (verified 2026-10-02).

Sample EPA 608 questions

Worked examples with the answer explained — the same teaching you get after every question in practice. Original questions written by Keentune, not real exam items.
Core rules
Before opening a refrigerant system for major service, what does the Clean Air Act require a technician to do with the refrigerant?
• Recover it
• Vent it slowly outdoors
• Mix it with nitrogen first
• Let it boil off
Answer: Recover it
Section 608 prohibits knowingly venting (releasing) regulated refrigerant to the atmosphere, so it must be recovered — removed and stored in an approved container. The trap is any option that lets it escape: there’s no “slow” or “outdoor” exception (only a few tiny de minimis releases during a good-faith recovery attempt are allowed). Rule: recover, never vent — the three Rs are recover, recycle, reclaim.
Recovery — Type I
Recovering from a small appliance whose compressor is NOT running, using recovery equipment made on or after November 15, 1993, to what level must the refrigerant be recovered?
• 80%, or a 4-inch mercury vacuum
• 100% — a full evacuation every time
• 25%, then recycle the rest
• Any amount, then vent the rest
Answer: 80%, or a 4-inch mercury vacuum
For small appliances (Type I), recovery equipment made on or after Nov 15, 1993 must pull 90% of the charge when the appliance’s compressor is running, or 80% when it isn’t — or reach a 4-inch mercury (inHg) vacuum. Compressor off means the 80% / 4-inHg standard. The trap is “100%”: a full evacuation isn’t required for small appliances, only these levels. Rule: Type I = 90% (compressor on) / 80% (compressor off), or 4 inHg.

Practice by section

Core — rules & refrigerants
Ozone science, GWP and refrigerant safety classes (A1, A2L, A3), the venting prohibition, certification types, sales restriction, the three Rs, and cylinder safety.
Types I–III — service practices
Recovery methods and required levels, evacuation and deep vacuum, leak testing, and low-pressure chiller procedures.
Original practice aligned to the public EPA Section 608 requirements (40 CFR Part 82) — never actual exam questions. Keentune is independent study practice, not affiliated with the EPA or any EPA-approved certifying organization, and does not guarantee a pass. EPA is a US government agency; Section 608 program names are used here for identification only.
Start practicing — it’s free
Explore all skills on Keentune

More exam prep

SAT practice
ACT practice
GRE practice
GMAT practice
LSAT practice
IELTS practice
TOEFL practice
ASVAB practice
IQ / Mensa practice
CCAT practice
Wonderlic practice
PI Cognitive Assessment practice
GED practice
PSAT/NMSQT practice
Duolingo English Test practice
US Citizenship practice
ISEE / SSAT practice
Watson-Glaser practice
BMCT practice
SHL / Korn Ferry practice
Coding interview practice
System design interview practice
Frontend interview practice
Mobile interview practice
Behavioral interview practice
Backend interview practice
CKA practice
AWS Solutions Architect practice
CompTIA Network+ practice
CompTIA Security+ practice
SIE practice
ServSafe Manager practice
Real Estate Exam practice
FAA Part 107 practice
Basketball Officiating practice
Football Officiating practice
Soccer Refereeing practice
Baseball Umpiring practice
PTCB practice
MCAT practice
AP Biology practice
AP Chemistry practice
AP Physics practice
AP Statistics practice
Police Exam practice
Civil Service Exam practice
Firefighter Exam practice
Job Aptitude Test practice
TEAS practice
HESI A2 practice
Series 63 practice
Series 65 practice
Series 66 practice
Series 7 practice
Praxis Core practice
USPS Postal Exam practice
EEI CAST & POSS practice
Ramsay Mechanical Test practice
SIFT practice
Navy OAR practice
AFOQT practice
Homeschool Practice practice
NCLEX-RN practice
CDL practice
EMT practice
CompTIA A+ practice
PMP practice
CISSP practice
CPC (Medical Coding) practice
Private Pilot (PAR) practice
Terraform Associate practice
Volleyball Officiating practice
CPA Exam practice
AP Calculus practice
AP Psychology practice
AP Microeconomics practice
AP Macroeconomics practice
Boating License practice
Browse the Careers & Licensing category

EPA 608 practice — FAQ

Does an EPA 608 certification expire?

No. Section 608 technician certification doesn’t expire, and there’s no renewal or continuing-education requirement (as of 2026 — the rule reserves EPA’s right to add recertification in the future). Technicians certified on an older exam stay certified when a certifying organization updates its questions.

Is there a new EPA 608 exam in 2026?

The certification and its format haven’t changed: the federal rules for the test (40 CFR Part 82, Appendix D) were last amended in 2016, and it is still Core plus Types I, II and III at 25 questions each. What changes is the question bank. ESCO Institute, one EPA-approved certifying organization, released an updated Section 608 test bank in August 2026 and lists its 2018 exam as available until January 1, 2027, with separate study materials and pressure-temperature charts for each (as of October 2026). If you test through ESCO, check which edition you are booked on and study the matching materials. Keentune’s practice is written from the current regulations — including the AIM Act rules for HFCs and the A2L and A3 refrigerant safety classes — rather than from any organization’s question bank, so it isn’t keyed to either edition.

What’s the difference between Type I, II, III, and Universal?

Type I covers small appliances, Type II high-pressure systems, and Type III low-pressure chillers — each a separate 25-question section. Passing Core plus all three types earns Universal certification, which covers every category.

What score do I need to pass the EPA 608 exam?

The rule sets the closed-book passing score at 70% per section, which on 25 questions means 18 correct (17 is 68%). Each section is scored independently: you keep the sections you pass, and if you miss one type you generally retake only that section (retake rules and fees vary by certifying organization).

How much does the EPA 608 exam cost?

It varies by the EPA-approved certifying organization — roughly $20 to $150 depending on whether you test online, proctored, or by mail, and how many types you take (cost as of 2026 — check your testing provider).

Is the EPA 608 exam open-book?

Type II, Type III and Universal must be taken closed-book and proctored. The rule also allows a mail-in Type I format, which requires a higher 84% to pass, and EPA says a Core section taken open-book can’t be used toward Universal. Not every organization offers the mail-in option (as of 2026).

Do the leak-repair rules apply to HFC systems?

Since January 1, 2026, many of them, yes. The older Section 608 rule now covers only appliances holding 50 pounds or more of an ozone-depleting refrigerant (such as R-22). The AIM Act’s Emissions Reduction and Reclamation rule (40 CFR Part 84) applies leak repair to appliances holding 15 pounds or more of an HFC refrigerant, except residential and light-commercial air conditioning and heat pumps. Both work the same way: calculate the leak rate each time refrigerant is added, repair within 30 days when it is over the threshold for the appliance’s category, and verify the repair. Thresholds and dates are set by rulemaking and change, so check epa.gov for current values before your exam (as of October 2026).

Do I need EPA 608 certification?

Federal law (Clean Air Act Section 608) requires certification for any technician who maintains, services, repairs, or disposes of equipment that could release regulated refrigerants — ozone-depleting refrigerants and their non-exempt substitutes, such as HFCs.
Also on your phone
All exam, test, and product names and trademarks are the property of their respective owners and are used here for identification and reference only. Keentune is independent study practice — not affiliated with, authorized, or endorsed by any of these organizations.
© 2026 SportaApp LLC